SMART INDICATOR
DM4000 Series
|
- Universal, Pulse or
Flow Measurement
- 6 Digit display
- Front Panel Sealed to NEMA
4
- Analog Output Option
- 1, 2, 3 or 4 Alarm Option
- RFI Protected Metal Case
- Serial Communications
- Rate or Total Display
- 5 Year Warranty
|
|
|
INTRODUCTION
The
DM4000 is a highly accurate digital process
indicator, available in three versions:
| DM4000U |
accepts common
industrial sensors |
| DM4000C |
accepts various
types of pulse inputs to provide RATE and
TOTAL functions. |
| DM4000A |
is a dedicated
Flow Computer accepting analog inputs and
providing RATE and TOTAL functions. |
A wide range of options are available enabling
the DM4000 to be used in a variety of applications.
Two output slots are provided, each of which can
accept either a single or dual alarm relay output,
an isolated 4 to 20 ma output card or a bridge
excitation card. A dedicated communications
slot is also provided which can accept an RS485
serial digital communications card.
The sensor type and range are user
configurable, either from the front panel or via
the optional serial communications port.
All ranges are fully calibrated which means the
user can change quickly and easily from one sensor
type to another. The analog outputs can
be any part of the incoming range allowing the
DM4000 to be used as a 'smart' sensor transmitter.
The NEMA 4 sealed front panel protects
the DM4000 against environmental conditions
such as water and dust.
Reduced stock holding due to the
versatility of the DM4000 combined with
it's exceptional accuracy and stability and 5
year warranty, provides for a 'low cost of
ownership'.
APPLICATIONS
- Process monitoring
- Strain gage measurement
- Flow measurement
- Alarm monitoring
- Data logging
- Batch controlling
- Speed measurement
- Data Acquisition
GENERAL FEATURES
Display - When used as an analog
or frequency indicator, 5 digit resolution is
provided. The Totalizer has 12 digit resolution
displayed in two 6 digit displays. Display
update rate is 13.3 Hz.
Programming - All
parameters can be entered from 3 keys on the from
panel or via the optional communications port.
Programming is done by pressing combinations of
the three sealed front panel keypads through a
series of menus which are displayed on the 6 digit
display in helpful mnemonics. Lack of keypad
use returns the instrument to the run mode.
The keys are used individually to review setpoints
and clear latched alarms.
Communications
- RS485 communications are optional. By
using an RS485/232 converter unit, up to 99 DM4000s
may be connected to a host computer to allow access
to all configuration and process variable information.
In addition, the Remote Configuration Package
(RCP4000) is available which allows rapid configuration
via a PC. Although 99 DM4000s can be interfaced
on the network RS485 requires additional buffering
for more than 32 units.
Front Panel - The
front panel membrane is sealed to NEMA 4.
User replaceable legends and identifying tags
are protected by the membrane.
Filter - The input
has a programmable 'Smart' digital filter which
can be used to smooth out noisy signals.
Self Testing -
Background self testing is continuous and an internal
watchdog monitors the correct operation of the
internal microprocessor.
|
OUTPUTS
Two output slots are provided which can accept
a variety of output option cards.
- 1, 2, 3 or 4 alarm relays/pulse outputs
- 4 to 20 ma isolated analog outputs
- Programmable excitation voltage
All alarms can be: High, Low
or Deviation and have programmable hysterisis. They
can be set to fail safe high or low and can be latching
or non-latching. The analog output can be any part
of the input range.
In the DM4000A and C versions
the relay output can be programmed to give a 100 ms output
at decade intervals from the TOTAL display. (e.g..
every 10 GAL or 100 GAL etc.)
OPTIONS SPECIFICATIONS @ 68 °F
| .OPTION
01 |
.Single
Relay Output Card |
| .Relay |
.Single
programmable alarm relay.
.Normally open and
normally closed output available. |
| .Rating |
.8
amps @ 240 V |
| .Isolation |
.500
V with respect to inputs* |
| |
| .OPTION
02 |
.Dual
Relay Output Card |
| .Relay |
.Two
independently programmable alarms sharing the same
common. |
| .Rating |
.8
amps @ 240 V |
| .Isolation |
.500
V with respect to inputs* |
| |
| .OPTION
03 |
.Current
Output |
| . |
.The
output can be driven by either an internal or external
power source. |
| .Accuracy |
.<0.1%
of full scale |
| .Resolution |
.<0.1%
of full scale (>10% of the input range) |
| .Power |
.Internal
supply will drive into 700 ohms
.External loop voltage
10 to 30 VDC |
| .Isolation |
.500
V with respect to inputs* |
| .Response |
.<100
ms for 63% step change |
| .Output |
.Minimum
0 ma
.Maximum 22 ma |
| |
| .OPTION
04 |
.Bridge
Excitation (Strain Gage) |
| |
.This
provides either a programmable 2 to 20 VDC output
.or a fixed 24 VDC
stable output |
| .Range |
.2
to 24 VDC |
| .Accuracy |
.<0.1%
of full scale |
| .Isolation |
.500
V with respect to inputs* |
| .Stability |
.<56
ppm/ºF |
| .Output |
.50
ma max. (less current consumed by other output slot) |
| .Ripple |
.<0.05%
full scale @ 50 ma |
| NOTES.... |
..*
Isolation is supplied between inputs, outputs and
communication slots but not between two analog output
slots. |
ENVIRONMENTAL SPECIFICATION
| .Ambient
Temp. Range |
.32
to 122 ºF |
| .Relative
Humidity |
.5
to 95% RH non-condensing |
| .Isolation |
.Inputs
fully isolated 500 V |
| .Power
Supply |
.120
VAC 50/60 Hz
.240 VAC 50/60 Hz
.24 VAC 50/60 Hz
.fully isolated to
1.5 KV |
DM4000U - UNIVERSAL
INPUT PROCESS INDICATOR
The DM4000U is
a universal digital indicator which can be configured from
the front panel to take all common industrial sensors without
the need to change option boards or move jumpers.
There are two output slots which can accept any of the optional
output boards.
DM4000U SPECIFICATIONS @ 68 °F
| .THERMOCOUPLE |
± ACCURACY*
|
RESOLUTION** |
NOMINAL RANGE
|
| .TC
Type K |
2 ºF |
0.1 ºF |
-454 to
2192 ºF |
| .TC
Type J |
2 ºF |
0.1 ºF |
-346 to
1400 ºF |
| .TC
Type T |
2 ºF |
0.1 ºF |
-454 to
752 ºF |
| .TC
Type R |
4 ºF |
0.5 ºF |
+32 to
3182 ºF |
| .TC
Type S |
4 ºF |
0.5 ºF |
+32 to
3182 ºF |
| .TC
Type E |
2 ºF |
0.5 ºF |
+32 to
1202 ºF |
| .TC
Type F |
2 ºF |
0.5 ºF |
+32 to
1112 ºF |
| .TC
Type N |
2 ºF |
0.5 ºF |
+32 to
2372 ºF |
| .TC
Type B |
4 ºF |
0.5 ºF |
+1832
to 3272 ºF |
| .Cold
Junction |
1 ºF |
0.1 ºF |
+32 to
122 ºF |
|
.RTD
|
± ACCURACY
|
RESOLUTION |
NOMINAL RANGE
|
| .Pt100 |
0.2 ºF±0.1%
of reading |
0.02 ºF |
-328 to
1472 ºF |
|
.VOLTAGE
|
± ACCURACY
|
RESOLUTION |
NOMINAL RANGE
|
| .10
Volts |
0.02%
of full scale |
0.004% |
-10 to
+10 V |
| .1
to 5 Volts |
0.04%
of full scale |
0.008% |
1 to +5
V |
| .1
volt |
0.02%
of full scale |
0.004% |
±1 V |
| .100
mV |
0.02%
of full scale |
0.004% |
±0.1 V |
|
.CURRENT
|
± ACCURACY
|
RESOLUTION |
NOMINAL RANGE
|
| .4
to 20 ma |
0.1% of
full scale |
0.004% |
4 to 20
ma |
| .0
to 20 ma |
0.1% of
full scale |
0.004% |
0 to 20
ma |
| .0
to 10 ma |
0.2% of
full scale |
0.008% |
0 to 10
ma |
A/D conversion rate is 10 per second
| .Notes: |
.*
.**
|
Accuracy
includes linearization and cold junction tracking
errors for a 50 ºF to 104 ºF
ambient temperature for thermocouple inputs.
Resolutions shown are theoretical maximums, however,
resolution is programmable as is the position of
the decimal point for engineering ranges.
A/D resolution is 1 part in 25,000 (approximately
15 Bit plus sign) |
USER LINEARIZATION
A user defined linearization table is provided
for non-linear functions. In addition, the user can
select a square root, power 3/2 or power 5/2 function.
All displays are in engineering units. This feature
is only available for voltage and current inputs.
FIELD TRANSMITTER
SUPPLY
An internal 21 VDC supply to power two wire
4 to 20 ma field transmitters is standard. A programmable
excitation supply for transducers is available as an option.
DM4000C - PULSE INPUT
RATE or TOTAL INDICATOR
The DM4000C accepts all
types of pulse inputs and provides a choice of RATE or TOTAL
displays. RATE is in engineering units and TOTAL can
have its own scaling. The TOTAL can be reset locally
from the front or remotely from an external contact and
is stored during power down.
The instrument has two individual
inputs channels 'a' and 'b'. Either
channel may be designed as the prime frequency input channel
or alternatively as the control channel. User selection
of channels is determined by the type of input.
Input signals accommodated by the channels
are as follows:
| Input
Type |
Channel |
| Volt free
contact |
a,
b |
| TTL Input |
b |
| 10 mv
low level Input |
b |
| NAMUR
compatible signals |
a |
| Open collector
NPN |
b |
| Open collector
PNP |
a |
Frequency Range
0.03 Hz to 50 Hz for potential free contacts
0.03 Hz to 20K Hz for all other input types
Debounce
A 4 ms Debounce is available to eliminate edge jitter for
frequencies below 50 Hz.
Frequency Measurement
The incoming frequency is measured by a combination of period
measurement and pulse counting. A 100 ms window is
used for all incoming frequencies above 10 Hz. This
is called the capture window. For frequencies below
10 Hz the capture window becomes the actual incoming period.
The following table illustrates the point.
| .Frequency |
<0.03 |
0.03
to 10 |
10
to 20K |
20K
to 25K |
| .Capture
Window |
30 sec****** |
Period*
& ****** |
100
mS |
| .Display***** |
Lo** |
Frequency
Totalize*** |
Over**** |
| .Notes: |
.*
.**
.***
.****
.*****
.******
|
Period
is actual incoming period
Lo is engineering low range
Frequency and Total are scaled in engineering units
OVER is overrange
Display refresh rate is always 3.3 Hz
Capture window is halved when Debounce is selected
(Below 50 Hz) |
Characterization
A 12 point user linearization table is provided as is selectable
'Cut lo' feature which automatically sets the Rate to engineering
low range for frequencies that fall below this programmable
value. Relay options may be configured as alarms or
pulse output if used in conjunction with total.
FIELD TRANSMITTER
SUPPLY
An internal 8 VDC power supply to power field
transmitters is standard.
DM4000A - ANALOG INPUT
FLOW COMPUTER INDICATOR
The DM4000A is
a combination of the analog input handling of the DM4000U
with RATE and TOTAL functions of the DM4000C
providing a special instrument designed for flow measurement
applications.
The input can be either voltage
or current and it is normally used in conjunction with a
differential pressure sensor and some type of restriction
e.g. orifice plate, flume, rectangular or 'V' weirs, to
provide a digital representation of flow.
DM4000A SPECIFICATIONS @ 68 °F
| Sensor |
± Accuracy |
Resolution |
Nominal
Range |
| .Voltage |
| ± 10 Volts |
0.02%
FS |
0.004% |
± 10
V |
| 1 to 5
Volts |
0.04%
FS |
0.008% |
1V to
+5 V |
| ± 1 Volt |
0.02%
FS |
0.004% |
±1 V |
| ± 100
mv |
0.02%
FS |
0.004% |
±0.1 V |
| .Current |
| 4 to 20
ma |
0.1% FS |
0.004% |
4 to 20
ma |
| 0 to 20
ma |
0.1% FS |
0.004% |
0 to 20
ma |
| 0 to 10
ma |
0.2% FS |
0.008% |
0 to 10
ma |
| .Characterization |
.Linear |
| .Square
Root (Orifice Plate) |
| .Power
3/2 (Rectangular Weir/Flume) |
| .Power
5/2 (45 degree V Weir) |
| .User:
User defined 13 points |
| .Display |
.Rate:
5 digits |
| .Totalize:
6 digits + 6 overflow |
| .Special
Feature |
.Programmable
100 ms pulse output |
| .(when
option 01 or 02 are fitted) |
The appropriate characterization can be selected from the
front panel and the display scaled in linear flow units.
In addition, a 13 point user defined characterization is
available for the more unusual applications.
The display may be selected to
show RATE or TOTAL; TOTAL having its own user programmable
scaling. When displaying flow RATE, totalizing is
performed in the background and pressing a front panel key
provides a 'View' facility. If TOTAL is selected
as the main display, it is possible to 'View' the instantaneous
RATE.
Output options can be dedicated
to either RATE or TOTAL and the TOTAL is maintained during
power down stored in EEPROM.
In addition, the relay output
option can be configured as a pulse output giving a contact
closure for 100 ms every time there is a change in a particular
selectable digit on the TOTAL display, i.e. the contact
will close for 100 ms say every 100 gallons. This
provides a low cost means of interfacing with data logging
systems or to drive additional secondary counters.
FIELD TRANSMITTER
SUPPLY
An internal 21 VDC supply to power two wire
4 to 20 ma field transmitters is standard. A programmable
excitation supply for transducers is available as an option.
ORDER CODE
DM4000(Type) / Option 1 / Option
2 / Comms / Supply
| .DM4000
Basic Model Number |
| .Type |
.U
= Universal Input
.C = Pulse Input
.A =Flow Computer |
| .Options |
.01
= Single programmable alarm relay 8 amps single
pole.
.02 = Dual
independently programmable alarm relays 8 amps single
pole, N/C (shared common).
.03 = 4
to 20 ma isolated analog output or a voltage output
by the addition of an external resistor.
.04 = 2
to 20 VDC programmable plus 24 VDC transducer excitation
voltage. |
| .Communications |
.000
= No Communications
.485 =RS485
comms - multi drop |
| .Supply |
.240
= 240 VAC 50/60 Hz
.120 = 120 VAC
50/60 Hz
...24 =
24 VAC 50/60 Hz |
ACCESSORIES
| ACC4000-01 |
Wall mounted enclosure
to NEMA 4 |
| ACC4000-02 |
Adaptor for 1/4 to 1/8
DIN |
| ACC4000-03 |
Spare 3 way connector |
| ACC4000-04 |
Spare Handbook |
| ACC4000-05 |
Spare 5 way connector |
| ACC4000-06 |
Pack of 10 sealed gaskets |