ISOLATING
THERMOCOUPLE
TRANSMITTER
SEM1500TC
|
 |
- Universal
Thermocouple
Input
- Galvanically
Isolated
- Small
Size
- 4
to
20
ma
Output
- High
Performance
- DIN
Rail
Mount
|
|
INTRODUCTION
The
SEM1500TC
is
a
universal
thermocouple
input
DIN
rail
mounted
transmitters
designed
to
accept
most
common
thermocouple
types
and
to
isolate
and
convert
them
to
the
industry
standard
4
to
20
ma
transmission
signal.
Automatic
cold
junction
compensation
is
provided.
The
unit
can
also
accept
millivolt
inputs
between
-5
and
+50
millivolts
from,
for
example,
strain
gages.
The
small
size
of
the
unit
enables
many
more
units
to
be
installed
in
a
smaller
space
than
was
previously
possible.
The
output
signal
is
galvanically
isolated
from
the
thermocouple
by
500
VDC
to
remove
the
effects
of
ground
loops
or
leakage.
|
INPUT
SPECIFICATION
@ 68
°F
| .Thermocouple
Types |
.J,
K,
N,
R,
S,
T |
| .Millivolt |
.-5
to
50
mv
signals |
| .Isolation |
.INPUT
to
OUTPUT
.500
VDC
(Flash
tested
to
1
kV) |
| .Burn
Out |
.UP
scale
standard
(DOWN
scale
to
order) |
| .Impedance |
.>
1M
ohm |
| .Cold
Junction |
.Automatic
compensation
may
be
selected
for
use
with
T/C
types
indicated
or
fixed
zero
compensation
may
be
selected
for
mv
or
differential
T/C
measurement. |
| .CJ
Accuracy |
.±0.4
ºF
@
68
ºF
±0.02
ºF/ºF
Typical |
OUTPUT
| .Type |
.Passive
2
wire
current
output |
| .Range |
.4
to
20
ma
(30
ma
max.) |
| .Linearity |
.mv
input
linearity
±0.005%
.T/C
ranges
are
cold
junction
compensated
and
directly
referenced
to
T/C
mv
values. |
| .Protection |
.Reverse
connection
plus
over
voltage |
GENERAL
SPECIFICATIONS
| .Supply |
.10
to
30
VDC |
| .Load |
.700
ohms
@
24
V |
| .Thermal
Stability |
.1
µV/ºF
.plus
cold
junction
errors |
| .Ripple
Refection |
.<40
µA/V
(measured
at
1
V
ripple
60
Hz) |
| .Response
time |
.200
ms
to
reach
70%
of
final
value |
| .Operating
Temperature |
.Ambient
32
to
158
ºF |
| .Relative
Humidity |
.Ambient
10-95%
non-condensing |
APPROVALS
| .Tested
to: |
|
| .IEC
801-2 |
.Susceptibility
to
electrostatic
discharge |
| .IEC
801-3 |
.Radiated
Susceptibility |
| .IEC
801-4 |
.Susceptibility
to
conducted
interference |
| .EN
55022 |
.Radiated
emissions |
ENCLOSURE
| .Case
Material |
.Polyamide
(Grey) |
| .Case
Flammability |
.To
UL94-VO
VDE
0304
Part
3
Level
IIIA |
| .Mounting |
.Top
Hat
rail
to
DIN
EN
50022-35 |
| .Protection |
.IP20 |
| .Connections |
.Captive
screw
connections |
| .Cable
Size |
.12
AWG
solid
/
14
AWG
stranded |
STANDARD
RANGES
The
SEM1500TC
may
be purchased
pre-ranged
to any
of the
following
standard
ranges:
Range
ºF
from
to |
Range
ºC
from
to |
THERMOCOUPLE
TYPE |
millivolt
V |
| N |
K |
T |
J |
R |
S |
| 32
212 |
0
100 |
* |
* |
* |
* |
|
|
|
| 32
392 |
0
200 |
* |
* |
* |
* |
|
|
|
| 32
752 |
0
400 |
* |
* |
* |
* |
|
|
|
| 32
1112 |
0
600 |
* |
* |
|
* |
|
|
|
| 32
1472 |
0
800 |
* |
* |
|
* |
|
|
|
| 32
1832 |
0
1000 |
* |
* |
|
|
* |
* |
|
| 32
2192 |
0
1200 |
* |
* |
|
|
* |
* |
|
| 32
2912 |
0
1600 |
|
|
|
|
* |
* |
|
Range
mv
0
50
mv |
Range
mv
0
50
mv |
|
* |
NON
STANDARD
RANGES
Units
can
be supplied
set
up to
other
non-standard
ranges
for
a small
extra
charge
or alternatively
the
unit
can
easily
be re-ranges
as follows:
ADJUSTMENTS
(Range
selection)
Range
selection
GAIN
and
OFFSET
Coarse
settings
are
made
by two
16 position
rotary
screw
adjustment
switches
on the
side
of the
unit.
Fine
adjustment
is by
front
access
potentiometers.
Full
re-calibration
details
are
supplied
with
each
transmitter.
| INPUT
type |
OFFSET
RANGE
ºF |
GAIN
RANGE
ºF |
OFFSET
RANGE
ºC |
GAIN
RANGE
ºC |
| |
at
4
ma |
4
to
20
ma |
at
4
ma |
4
to
20
ma |
| K
T/C |
-328
to
752 |
212
to
2192 |
-200
to
400 |
100
to
1200 |
| T
T/C |
-328
to
752 |
212
to
2192 |
-200
to
300 |
100
to
400 |
| J
T/C |
-328
to
752 |
158
to
1382 |
-200
to
400 |
70
to
750 |
| N
T/C |
392
to
752 |
302
to
2192 |
200
to
400 |
150
to
1200 |
| R
T/C |
32
to
1832 |
932
to
3092 |
0
to
1000 |
500
to
1700 |
| S
T/C |
32
to
1832 |
932
to
3200 |
0
to
1000 |
500
to
1760 |
| V
mv |
-5
to
+15
mv |
3
to
50
mv |
-5
to
+15
mv |
3
to
50
mv |
SEM1500TC
Instruction
Manual
ORDER
CODE
| SEM1500
/
Input
Type
/ |
value
@
4
ma
/ |
value
@
20
ma
/ |
ºF
or
ºC
|
Call
(713) 861-1100 for literature and pricing.