SMART
RAIL
MOUNTED
TRANSMITTER
/
CONDITIONER
SEM220
and
SEM230
|
 |
- Smart
- DIN
Rail
Mounted
- Intrinsically
Safe
Option
- Universal
Input
- Isolation
- Very
Stable
|
|
INTRODUCTION
Smart
transmitters
provide
better
accuracy
and
stability
than
their
analog
counterparts,
greater
flexibility
and
the
ability
to
interface
with
a
Personal
Computer
or
Process
control
System.
This
means
that
sensors
and
ranges
can
be
changed
without
the
need
for
re-calibration
or
jumper
changes.
The
SEM220
&
SEM230
Smart
DIN
Rail
Transmitters
provide
current
output
(or
a
voltage
by
the
addition
of
an
external
resistor)
from
any
of
the
common
industrial
sensors.
All
versions
feature
isolation
from
the
power
supply
and
input
to
output
isolation.
The
SEM230
can
have
an
optional
dual
relay
alarm,
and
the
SEM230XM
is
a
version
with
FM
approval
for
use
with
sensors
in
hazardous
areas
without
the
use
of
barriers.
ACCURACY
and
STABILITY
The
are
micro-processor
based
and
feature
automatic
self
calibration
of
span
and
zero
which
results
in
excellent
short
and
long
term
accuracy
and
repeatability.
Linearization
is
performed
digitally
to
ensure
drift
free
performance.
|
INPUT
SPECIFICATION
@
68
°F
| .THERMOCOUPLE |
±
ACCURACY
|
RESOLUTION |
NOMINAL
RANGE
|
| .TC
Type
K |
2
ºF |
0.1
ºF |
-454
to
2192
ºF |
| .TC
Type
J |
2
ºF |
0.1
ºF |
-346
to
1400
ºF |
| .TC
Type
T |
2
ºF |
0.1
ºF |
-454
to
752
ºF |
| .TC
Type
R |
4
ºF |
0.5
ºF |
+32
to
3182
ºF |
| .TC
Type
S |
4
ºF |
0.5
ºF |
+32
to
3182
ºF |
| .TC
Type
E |
2
ºF |
0.5
ºF |
+32
to
1202
ºF |
| .TC
Type
F |
2
ºF |
0.5
ºF |
+32
to
1112
ºF |
| .TC
Type
N |
2
ºF |
0.5
ºF |
+32
to
2372
ºF |
| .TC
Type
B |
4
ºF |
0.5
ºF |
+1832
to
3272
ºF |
| .Cold
Junction |
1
ºF |
0.1º
F |
+32
to
122
ºF |
|
.RTD
|
±
ACCURACY
|
RESOLUTION |
NOMINAL
RANGE
|
| .Pt100 |
0.2
ºF±0.1%
of
reading |
0.02
ºF |
-328
to
1472
ºF |
|
.VOLTAGE
|
±
ACCURACY
|
RESOLUTION |
NOMINAL
RANGE
|
| .10
Volts |
0.02%
of
full
scale |
0.004% |
-10
to
+10
V |
| .5
Volts |
0.04%
of
full
scale |
0.008% |
-5
to
+5
V |
| .1
to
5
Volts |
0.04%
of
full
scale |
0.008% |
1
to
+5
V |
| .1
Volt |
0.02%
of
full
scale |
0.004% |
±1
V |
| .500
mv |
0.04%
of
full
scale |
0.008% |
±0.5
V |
| .100
mv |
0.02%
of
full
scale |
0.004% |
±0.1
V |
| .50
mv |
0.02%
of
full
scale |
0.004% |
±0.05
V |
|
.CURRENT
|
±
ACCURACY
|
RESOLUTION |
NOMINAL
RANGE
|
| .4
to
20
ma |
0.1%
of
full
scale |
0.004% |
4
to
20
ma |
| .0
to
20
ma |
0.1%
of
full
scale |
0.004% |
0
to
20
ma |
| .0
to
10
ma |
0.2%
of
full
scale |
0.008% |
0
to
10
ma |
|
.SLIDEWIRE
|
±
ACCURACY
|
RESOLUTION |
NOMINAL
RANGE
|
| .Slidewire |
0.1%
of
full
scale |
0.004% |
100
to
50K
ohms |
OUTPUT
PERFORMANCE
(source
or
sink)
| .Maximum
loop
impedance |
.1000
ohms
(source) |
| .Accuracy |
.20
µA
(0.1%
of
max.
current) |
| .Resolution |
.2
µA
(0.01%
of
max.
current) |
| .Response |
.100
ms
for
63%
of
step
change |
| .Minimum
current |
.0
ma |
| .Maximum
current |
.21
ma
approximately |
| .Thermal
drift |
.500
nA/ºF
(0.0025%
of
Max.
current/ºF) |
| .Ripple
current |
.Approximately
5
µA |
| Voltage
output
requires
a
resistor
installed
on
the
output
terminals.
Outputs
are
capable
of
driving
into
1000
ohms. |
GENERAL
SPECIFICATIONS
| .Isolation |
| |
.Input/Output |
.500
VAC |
| .PSU |
.1500
VAC |
| .Comms
I/F |
.500
VAC
(SEM230
only) |
| .Relay |
.500
VAC
(SEM230
only) |
| .Switch
Mode
Power
Supply |
| |
.S1 |
.90
to
264
VAC
50/60
Hz,
44
to
100
VDC |
| .S2 |
.22
to
28
VAC
50/60
Hz,
15
to
30
VDC |
| .S3 |
.90
to
130
VAC
50/60
Hz,
20
to
100
VDC |
| .Power
Consumption |
| |
.SEM220
4.5
W
maximum |
| .SEM230
6
W
maximum |
| .Ambient
Range |
| |
.Operating
32
to
122
ºF |
| .10
to
90%
RH
non
condensing |
| .Storage
-8
to
+176
ºF |
APPROVALS
| .EMI
Emissions |
.Designed
to
meet
EN55022 |
| .EMI
Susceptibility |
.Designed
to
meet
EN
50082-1
(BS6527) |
| .Safety |
.Designed
to
comply
with
IEC1010-1 |
SEM220
LOW
COST
SMART
TRANSMITTER
/
CONDITIONER
BENEFITS
The
SEM220
is
a
'SMART'
Transmitter/Conditioner
that
accepts
any
of
the
common
industrial
sensors
and
provides
isolation
between
input,
output
and
power
supply.
It
also
accepts
a
wide
range
of
current
and
voltage
inputs.
TEST
The
SEM220
is
micro-processor
based
and
features
automatic
self
calibration
of
span
and
zero
which
results
in
excellent
short
and
long
term
accuracy
and
repeatability.
All
linearization
is
performed
digitally
to
ensure
drift
free
performance.
These
feature
assure
a
high
degree
of
confidence
in
the
correct
operation
of
the
instrument
together
with
a
low
cost
of
ownership.
PROGRAMMING
Programming
is
achieved
by
means
of
a
host
computer
via
an
SEM200
interface
cable
to
a
connector
on
the
front
face
of
the
unit.
Programming
is
by
simple
menu
selections
presented
on
the
host
screen.
Sensors
and
ranges
can
be
changed
without
the
need
for
re-calibration
or
jumper
changes.
RS232
capability
is
provided.
CALIBRATION
The
unit
is
supplied
factory
calibrated.
Calibration
data
is
stored
in
EEPROM,
field
recalibration
is
possible
although
this
is
not
normally
necessary
for
5
years.
SYSTEM
HEALTHY
A
green
front
panel
LED
flashes
periodically
to
indicate
system
health
(OK).
A
steady
LED
indicates
that
an
error
condition
has
been
detected.
LED
off
indicates
a
loss
of
power.
A
fast
'flash'
indicates
the
sensor
is
under
or
over
range.
SEM230
EVEN
SMARTER
TRANSMITTER
/
CONDITIONER
BENEFITS
In
addition
to
all
the
features
of
the
SEM220,
the
SEM230
offers
the
following
additional
feature:
-
Additional
level
of
input
isolation
-
RS485
Multi-drop
Communications
-
Automatic
or
Programmable
cold
junction
-
Non-linear
input
(Square
root,
Power
3/2,
Power
5/2)
-
User
defined
linearization
-
FM
approval
-
24VDC
Internal
Transmitter
supply
-
Alarm
Relays
option
-
Output
Test
Connector
-
Intelligent
software
filter
-
Peak
&
Valley
Capture
/
Hold
-
Watchdog
Relay
option
-
Programmable
safety
condition
TEST
The
design
incorporates
a
WATCHDOG
and
a
programmable
safety
condition
(0
to
100%).
In
the
event
of
an
input
out
of
limits,
or
input
failure,
or
if
an
error
is
detected
and
the
transmitter
is
unable
to
continue
to
function
satisfactorily,
the
transmitter
goes
to
the
safety
condition,
and
the
system
health
LED
is
switched
permanently
on.
If
the
input
is
over
or
under
range,
the
LED
flashes
at
a
faster
rate.
In
practical
terms
it
is
not
possible
to
guarantee
that
all
potential
types
of
error
will
result
in
fail
safe
operation.
It
is
therefore
recommended
that
standard
process
control
procedures
are
followed;
that
in
critical
applications
a
secondary
back
up
system
is
employed.
ALARM
RELAYS
Alarm
relays
can
be
supplied
as
an
option.
These
are
two
individual
relays
with
a
common
connection
and
each
may
be
configured
independently
as
a
high,
low
or
deviation
alarm.
An
additional
feature
enables
the
relays
to
be
used
as
system
healthy
alarms.
Each
relay
has
an
associated
LED
which
is
illuminated
to
show
the
alarm
state.
ISOLATION
The
input,
output
and
communications
circuits
are
fully
isolated
from
each
other
to
500
VAC
rms.
All
circuits
are
isolated
from
the
power
supply
to
1.5
kV.
HAZARDOUS
AREAS
Two
versions
of
the
SEM230
are
available,
the
SEM230
for
general
applications
and
the
SEM230XM
for
hazardous
area
applications.
Although
both
versions
need
to
be
mounted
in
a
safe
area,
the
SEM230XM
has
an
isolated
and
intrinsically
safe
'front
end'
which
means
that
sensors
can
be
connected
directly
into
the
hazardous
area
WITHOUT
BARRIERS,
full
isolation
is
maintained
between
inputs
and
outputs.
The
IS
approval
is
by
FM
and
BASSEEFA
[EEx
ia]
IIC
and
sensors
can
be
mounted
in
Class
I,
II,
III,
Div
1,
GPS
A-G.
The
alarm
relay
option
can
also
be
used
provided
two
independent
trips
from
a
hazardous
area
sensor.
PROGRAMMING
Programming
is
achieved
using
a
standard
PC
via
a
connector
on
the
front
face
of
the
unit.
RS485
multi-drop
comms
is
standard,
enabling
32
x
SEM230s
to
be
connected
together
without
any
additional
interface.
Up
to
99
units
may
be
added
to
the
network
with
suitable
buffering.
Programming
is
by
simple
menu
selections
presented
on
the
host
screen.
REMOTE
DISCRETE
INPUTS
The
SEM230
can
accept
two
external
dry
contacts
(or
logical
inputs)
that
may
be
used
to
reset
or
inhibit
alarms
and
reset
peak/valley
memories
respectively.
INTERNAL
POWER
SUPPLY
| SEM230 |
24
V
@
24
ma
51
ohms |
| SEM230XM |
24
V
@
24
ma
351
ohms |
ORDER
CODE
SEMxxx
/
OPTION
/
SUPPLY
| .MODEL |
.SEM220
.SEM230
.SEM230XM
FM
Approved
|
SEM
220
SEM230
SEM230XM |
| .OPTIONS |
.SEM220
no
options
available
.SEM230
-
Dual
Relays |
00
01 |
.VOLTAGE
.SUPPLY |
.90
to
264
VAC
50/60
Hz,
44
to
100
VDC
.22
to
28
VAC
50/60
Hz,
15
to
30
VDC
.90
to
130
VAC
50/60
Hz,
20
to
100
VDC
.Note:
If
not
specified
S1
will
be
supplied |
S1
S2
S3 |